Ürün Ayrıntıları

Menşe yeri: Danimarka

Marka adı: PR

Sertifika: CO

Model numarası: PR 5115A

Belge: 5115v104_uk.pdf

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 1

Fiyat: 100-300usd

Teslim süresi: C4-Kuru meyve torbası

Ödeme koşulları: T/T

Yetenek temini: 99 adet 4-6 hafta

Şimdi konuşalım.
Vurgulamak:

PR 5115A Signal Calculator

,

RTD Signal Calculator

,

MV Signal Calculator

Başvuru:
Endüstriyel, HVAC, Otomotiv, Petrol ve Gaz
Montaj seçenekleri:
Panel, Duvar, Boru
Bağlantı türü:
Dişli, Flanşlı
Koruma derecesi:
IP65
Kesinlik:
±0,5% tam ölçek
Çalışma sıcaklığı:
-20°C ila 80°C
Malzeme:
Paslanmaz çelik
Ürün adı:
Basınç Ölçüm Cihazları
Ölçüm aralığı:
0 ila 1000 psi
Görüntüleme türü:
LCD/LED
Güç kaynağı:
24 V DC
Yanıt Zamanı:
1 saniyeden az
Çıkış Sinyali:
4-20 mA, 0-10 V, Dijital
Basınç tipi:
Ölçer, Mutlak, Diferansiyel
Başvuru:
Endüstriyel, HVAC, Otomotiv, Petrol ve Gaz
Montaj seçenekleri:
Panel, Duvar, Boru
Bağlantı türü:
Dişli, Flanşlı
Koruma derecesi:
IP65
Kesinlik:
±0,5% tam ölçek
Çalışma sıcaklığı:
-20°C ila 80°C
Malzeme:
Paslanmaz çelik
Ürün adı:
Basınç Ölçüm Cihazları
Ölçüm aralığı:
0 ila 1000 psi
Görüntüleme türü:
LCD/LED
Güç kaynağı:
24 V DC
Yanıt Zamanı:
1 saniyeden az
Çıkış Sinyali:
4-20 mA, 0-10 V, Dijital
Basınç tipi:
Ölçer, Mutlak, Diferansiyel
PR 5115A Signal Calculator Input For RTD Ohm TC MV MA Signals
Signal Calculator
PR 5115A
Redundancy measurement with 2 input signals • Signal calculator with four arithmetical operations • Duplication of input signal
Product Overview

Advanced signal calculator designed for industrial measurement and control applications. Supports multiple input types including RTD, Ohm, TC, mV, and mA signals with redundancy capability and mathematical operations.

Input Signal Compatibility
  • RTD inputs (Pt46, Pt100, Ni100, Cu53, linear R)
  • Thermocouple inputs (B, E, J, K, L, N, R, S, T, U, W3, W5, LR)
  • Current inputs (0...100 mA)
  • Voltage inputs (0...250 VDC)
  • mV inputs (-150...+150 mV)
Technical Specifications
Environmental Conditions
Operating temperature-20°C to +60°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degreeIP20
Mechanical Specifications
Dimensions (HxWxD)109 x 23.5 x 130 mm
Weight approx.225 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13...2.08 mm² AWG 26...14 stranded wire
Screw terminal torque0.5 Nm
Electrical Specifications
Supply voltage, universal21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse400 mA SB / 250 VAC
Max. required power2.1 W / 2.8 W (1 / 2 channel)
Isolation voltage, test/working3.75 kVAC / 250 VAC
AccuracyBetter than 0.05% of selected range
Response time250 ms...60 s (programmable)
Output Specifications
Current output range0...20 mA
Voltage output range0...10 VDC
Passive 2-wire mA output4...20 mA
Load capacity≤ 600 Ω (current output)
NAMUR NE43 compliance23 mA / 3.5 mA (Upscale/Downscale)
Certifications & Compliance
EMC2014/30/EU
LVD2014/35/EU
RoHS2011/65/EU
EACTR-CU 020/2011
DNV MarineTAA0000101