Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Industrial Sensors‌ > PR 6337D HART 7 protocol 2-wire transmitter RTD TC Ohm mV input 0.05% accuracy

PR 6337D HART 7 protocol 2-wire transmitter RTD TC Ohm mV input 0.05% accuracy

Product Details

Place of Origin: Denmark

Brand Name: PR

Certification: CO

Model Number: PR 6337D

Document: 6337v103_uk.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 200-400usd

Delivery Time: 5-7 work days

Payment Terms: T/T

Supply Ability: 99pcs 4-6 weeks

Chat now
Highlight:

2-wire HART transmitter for RTD signals

,

HART protocol pressure transmitter

,

dual-channel RTD TC converter

Measurementrange:
0 To 1000 Psi
Mountingoptions:
Panel, Wall, Pipe
Displaytype:
LCD/LED
Protectionrating:
IP65
Material:
Stainless Steel
Accuracy:
±0.5% FS
Responsetime:
≤ 1 Second
Productname:
Pressure Measurement Instruments
Outputsignal:
4-20 MA, 0-10 V, Digital
Application:
Industrial, HVAC, Automotive, Oil & Gas
Powersupply:
24 V DC
Operatingtemperature:
-20°C To 80°C
Connectiontype:
Threaded, Flanged
Pressuretype:
Gauge, Absolute, Differential
Measurementrange:
0 To 1000 Psi
Mountingoptions:
Panel, Wall, Pipe
Displaytype:
LCD/LED
Protectionrating:
IP65
Material:
Stainless Steel
Accuracy:
±0.5% FS
Responsetime:
≤ 1 Second
Productname:
Pressure Measurement Instruments
Outputsignal:
4-20 MA, 0-10 V, Digital
Application:
Industrial, HVAC, Automotive, Oil & Gas
Powersupply:
24 V DC
Operatingtemperature:
-20°C To 80°C
Connectiontype:
Threaded, Flanged
Pressuretype:
Gauge, Absolute, Differential
PR 6337D HART 7 protocol 2-wire transmitter RTD TC Ohm mV input 0.05% accuracy
2-wire HART Transmitter
PR 6337D
1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals with 2 analog inputs and 5 device variables with status available. HART protocol revision selectable.
Environmental Conditions
Operating temperature-40°C to +85°C
Storage temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP20
Mechanical Specifications
Dimensions (HxWxD)109 x 23.5 x 104 mm
Weight (1 / 2 channels)150 / 200 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13...2.08 mm² AWG 26...14 stranded wire
Screw terminal torque0.5 Nm
Common Specifications
Supply
Supply voltage8.0...30 VDC
Internal power dissipation, 1 / 2 ch.19 mW...0.7 / 1.4 W
Isolation Voltage
Isolation voltage, test / working1.5 kVAC / 50 VAC
Response Time
Response time (programmable)1...60 s
Voltage drop8.0 VDC
ProgrammingHART & PR 5909 Loop Link communications interface
AccuracyBetter than 0.05% of selected range
Signal dynamics, input22 bit
Signal dynamics, output16 bit
Signal / noise ratio> 60 dB
EMC immunity influence< ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span
Input Specifications
Common Input Specifications
Max. offset50% of selected max. value
RTD Input
RTD typePt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor currentNom. 0.2 mA
Linear Resistance Input
Linear resistance min....max.0 Ω...7000 Ω
TC Input
Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC)Constant, internal or external via a Pt100 or Ni100 sensor
Voltage Input
Measurement range-800...+800 mV
Min. measurement range (span)2.5 mV
Input resistance10 MΩ
Output Specifications
Current Output
Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply - 8) / 0.023 [Ω]
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Common Output Specifications
Updating time440 ms
HART protocol revisionsHART 7 and HART 5
Compliance & Certifications
Observed Authority Requirements
EMC2014/30/EU & UK SI 2016/1091
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approvals
ATEXDEKRA 20ATEX0108X
IECExDEK 20.0063X
CSA1125003
FMFM17US0013X
INMETRODEKRA 23.0011X
EAC ExEAEU KZ 7500361.01.01.08756
SILHardware assessed for use in SIL applications