Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Industrial Sensors‌ > PR 6335D HART 5 Protocol 2-Wire Transmitter Ex Zone 0 Installation 0.05% Accuracy

PR 6335D HART 5 Protocol 2-Wire Transmitter Ex Zone 0 Installation 0.05% Accuracy

Product Details

Place of Origin: Denmark

Brand Name: PR

Certification: CO

Model Number: PR 6335D

Document: 6335v111_uk.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 200-400usd

Delivery Time: 5-7 work days

Payment Terms: T/T

Supply Ability: 99pcs 4-6 weeks

Chat now
Highlight:

2-wire HART transmitter RTD input

,

HART 5 protocol pressure transmitter

,

Ex zone 0 compatible transmitter

Accuracy:
±0.5% Of Full Scale
Mounting:
Panel Mount Or Pipe Mount
Pressuretype:
Gauge, Absolute, Differential
Application:
Industrial, HVAC, Automotive
Material:
Stainless Steel
Calibration:
Factory Calibrated
Productname:
Pressure Measurement Instruments
Connectiontype:
1/4 Inch NPT
Operatingtemperature:
-20°C To 85°C
Powersupply:
24 V DC
Protectionrating:
IP65
Displaytype:
Digital LCD
Responsetime:
≤ 1 Ms
Measurementrange:
0 To 1000 Psi
Outputsignal:
4-20 MA, 0-10 V
Accuracy:
±0.5% Of Full Scale
Mounting:
Panel Mount Or Pipe Mount
Pressuretype:
Gauge, Absolute, Differential
Application:
Industrial, HVAC, Automotive
Material:
Stainless Steel
Calibration:
Factory Calibrated
Productname:
Pressure Measurement Instruments
Connectiontype:
1/4 Inch NPT
Operatingtemperature:
-20°C To 85°C
Powersupply:
24 V DC
Protectionrating:
IP65
Displaytype:
Digital LCD
Responsetime:
≤ 1 Ms
Measurementrange:
0 To 1000 Psi
Outputsignal:
4-20 MA, 0-10 V
PR 6335D HART 5 Protocol 2-Wire Transmitter Ex Zone 0 Installation 0.05% Accuracy
2-Wire HART Transmitter PR 6335D
Key Features
RTD, TC, Ohm, or mV input capability
Extremely high measurement accuracy
HART 5 protocol compatibility
Suitable for installation in Ex zone 0
Available in 1- or 2-channel versions
Environmental Conditions
Operating temperature -40°C to +85°C
Storage temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-condensing)
Protection degree IP20
Mechanical Specifications
Dimensions (HxWxD) 109 x 23.5 x 104 mm
Weight (1 / 2 channels) 145 / 185 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm² AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm
Common Specifications
Supply
Supply voltage 8.0...30 VDC
Internal power dissipation, 1 / 2 ch. 19 mW...0.7 / 1.4 W
Isolation Voltage
Isolation voltage, test / working 1.5 kVAC / 50 VAC
Response Time
Response time (programmable) 1...60 s
Voltage drop 8.0 VDC
Warm-up time 30 s
Programming HART & PR 5909 Loop Link communications interface
Signal / noise ratio Min. 60 dB
Accuracy Better than 0.05% of selected range
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
Input Specifications
Common Input Specifications
Max. offset 50% of selected max. value
RTD Input
RTD type Pt100, Ni100, lin. R
Cable resistance per wire 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor current Nom. 0.2 mA
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor error detection Yes
Linear Resistance Input
Linear resistance min....max. 0 Ω...7000 Ω
TC Input
Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC) < ±1.0°C
Sensor error detection Yes
Sensor error current: When detecting / else Nom. 33 μA / 0 μA
Voltage Input
Measurement range -800...+800 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Output Specifications
Current Output
Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Load stability ≤ 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
Common Output Specifications
Updating time 440 ms
of span = of the presently selected range
Compliance & Certifications
Observed Authority Requirements
EMC 2014/30/EU & UK SI 2016/1091
ATEX 2014/34/EU & UK SI 2016/1107
RoHS 2011/65/EU & UK SI 2012/3032
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Approvals
ATEX DEKRA 20ATEX0108X
IECEx DEK 20.0063X
CSA 1125003
FM FM17US0013X
INMETRO DEKRA 23.0011X
EAC Ex EAEU KZ 7500361.01.01.08756
SIL Hardware assessed for use in SIL applications