Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
produkty
produkty
Do domu > produkty > Industrial Sensors‌ > High Measurement Accuracy Programmable Transmitter PR 5333D With 3 Wire Connection Programmable Sensor Error Value

High Measurement Accuracy Programmable Transmitter PR 5333D With 3 Wire Connection Programmable Sensor Error Value

Szczegóły produktu

Miejsce pochodzenia: Dania

Nazwa handlowa: PR

Orzecznictwo: CO

Numer modelu: PR 5333D

Dokument: 5333v116_uk.pdf

Warunki płatności i wysyłki

Minimalne zamówienie: 1

Cena: 58

Czas dostawy: 5-7 dni roboczych

Zasady płatności: T/T

Możliwość Supply: 99 sztuk 4-6 tygodni

Rozmawiaj teraz.
Podkreślić:

High Measurement Accuracy Programmable Transmitter

,

Programmable Sensor Error Value Temperature Transmitter

,

3-Wire Connection RTD Transmitter

Kwiecień:
Nic
Moc pierwotna:
Wejście DC, 2-przewodowe
Kraj pochodzenia:
Wielkiej Brytanii i Tajlandii
Waga przesyłki:
5 kg
Dostępność:
w magazynie
Pamięć użytkownika:
48 MB
Producent:
CHORY
Enkodery absolutne:
AFS/AFM60 SSI
Czasy reakcji:
tak szybko, jak 90 ms
Medium pomiarowe:
Gaz i ciecz kompatybilne z 316LSS
Zasilanie:
24 V DC
Izolacja sygnału:
Izolacja galwaniczna
wilgotność względna:
5 do 95%, niekondensujące
aktualne:
4-20 Ma
Dokładności:
do 0,035% standardowo i 0,025% opcjonalnie
Kwiecień:
Nic
Moc pierwotna:
Wejście DC, 2-przewodowe
Kraj pochodzenia:
Wielkiej Brytanii i Tajlandii
Waga przesyłki:
5 kg
Dostępność:
w magazynie
Pamięć użytkownika:
48 MB
Producent:
CHORY
Enkodery absolutne:
AFS/AFM60 SSI
Czasy reakcji:
tak szybko, jak 90 ms
Medium pomiarowe:
Gaz i ciecz kompatybilne z 316LSS
Zasilanie:
24 V DC
Izolacja sygnału:
Izolacja galwaniczna
wilgotność względna:
5 do 95%, niekondensujące
aktualne:
4-20 Ma
Dokładności:
do 0,035% standardowo i 0,025% opcjonalnie
High Measurement Accuracy Programmable Transmitter PR 5333D With 3 Wire Connection Programmable Sensor Error Value
2-Wire Programmable Transmitter PR 5333D
  • RTD or Ohm input with high measurement accuracy
  • 3-wire connection configuration
  • Programmable sensor error value
  • Designed for DIN form B sensor head mounting
Environmental Conditions
Operating temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degree (enclosure/terminal)IP68 / IP00
Mechanical Specifications
DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm² stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6
2...25 Hz±1.6 mm
25...100 Hz±4 g
Common Specifications
Supply
Supply voltage8.0...30 VDC
Internal power dissipation25 mW…0.7 W
Response Time
Response time (programmable)0.33...60 s
Voltage drop8.0 VDC
Warm-up time5 min.
ProgrammingPR 5909 Loop Link communications interface
Signal / noise ratioMin. 60 dB
AccuracyBetter than 0.1% of selected range
Signal dynamics, input19 bit
Signal dynamics, output16 bit
Effect of supply voltage change< 0.005% of span / VDC
EMC immunity influence< ±0.5% of span
Input Specifications
Common Input Specifications
Max. offset50% of selected max. value
RTD Input
RTD typePt100, Ni100, linear R
Cable resistance per wire10 Ω (max.)
Sensor current> 0.2 mA, < 0.4 mA
Effect of sensor cable resistance (3-wire)< 0.002 Ω / Ω
Sensor error detectionYes
Linear Resistance Input
Linear resistance min....max.0 Ω...10000 Ω
Output Specifications
Current Output
Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply - 8) / 0.023 [Ω]
Load stability≤ 0.01% of span / 100 Ω
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Common Output Specifications
Updating time135 ms
of span= of the presently selected range
Intrinsic Safety / Ex Marking
ATEXII 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma
IECExEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
FM, USCl. I, Div. 1, Gp. A, B, C, D T4/T6; Cl. I Zone 0, AEx ia IIC T4/T6; Cl. 1, Div. 2, Gp. A, B, C, D, T4/T6
CSACl. I, Div. 1, Gp. A, B, C, D Ex ia IIC, Ga
INMETROEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
Compliance with Authority Requirements
EMC2014/30/EU
ATEX2014/34/EU
RoHS2011/65/EU
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approvals
DNV MarineTAA0000101
ATEXDEKRA 20ATEX0105X
IECExDEK 20.0062X
FMFM17US0013X
CSA1125003
INMETRODEKRA 23.0010X
EAC ExEAEU KZ 7500361.01.01.08756