Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
produits
produits
Maison > produits > Industrial Sensors‌ > Pt100 converter isolated transmitter 0.05% accuracy 6.1 mm slimline housing selectable response time

Pt100 converter isolated transmitter 0.05% accuracy 6.1 mm slimline housing selectable response time

Détails de produit

Lieu d'origine: Dénemark

Nom de marque: PR

Certification: CO

Numéro de modèle: PR 3112

Documents: 3112v107_en.pdf

Conditions de paiement et d'expédition

Quantité de commande min: 1

Prix: 200-400usd

Délai de livraison: 5-7 jours ouvrables

Conditions de paiement: T/T

Capacité d'approvisionnement: 99 pièces 4-6 semaines

Causez maintenant
Mettre en évidence:

Pt100 converter isolated slimline housing

,

Pt100 converter excellent accuracy

,

Pt100 converter EMC performance

Plage de tension de fonctionnement:
4.5 V CC... 32 V CC
Origine:
Thaïlande
Protection des entrées:
autres appareils pour la télécommunication
emballer:
en gros
Afficher:
Affichage LCD en option
Plage de mesure:
-200°C à 850°C
Canal:
32 chaînes
Pouvoir:
24 V CC (12-30) V CC
Mémoire utilisateur:
48 Mo
actuel:
4-20 mA
Code tarifaire:
853650800
CERF:
16 canaux 4 à 20 mA, HART
Sortir:
4-20 mADC/1-5 VCC
Taper:
Le numéro de série est le numéro de série de l'appareil
Signal de sortie:
4-20 mA
Plage de tension de fonctionnement:
4.5 V CC... 32 V CC
Origine:
Thaïlande
Protection des entrées:
autres appareils pour la télécommunication
emballer:
en gros
Afficher:
Affichage LCD en option
Plage de mesure:
-200°C à 850°C
Canal:
32 chaînes
Pouvoir:
24 V CC (12-30) V CC
Mémoire utilisateur:
48 Mo
actuel:
4-20 mA
Code tarifaire:
853650800
CERF:
16 canaux 4 à 20 mA, HART
Sortir:
4-20 mADC/1-5 VCC
Taper:
Le numéro de série est le numéro de série de l'appareil
Signal de sortie:
4-20 mA
Pt100 converter isolated transmitter 0.05% accuracy 6.1 mm slimline housing selectable response time
Pt100 Converter - Isolated
Model PR 3112
Excellent accuracy, better than 0.05% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable response time: < 30 ms / 300 ms
Environmental Conditions
Operating temperature-25°C to +70°C
Storage temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degreeIP20
Installation inPollution degree 2 & measurement/overvoltage category II
Mechanical Specifications
Dimensions (HxWxD)113 x 6.1 x 115 mm
Weight approx.70 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13...2.5 mm² / AWG 26...12 stranded wire
Screw terminal torque0.5 Nm
VibrationIEC 60068-2-6 compliant
Technical Specifications
Power Supply
Supply voltage16.8...31.2 VDC
Max. required power0.70 W
Max. power dissipation0.70 W
Isolation & Safety
Isolation voltage, test/working2.5 kVAC / 300 VAC (reinforced)
Zone 2 / Div. 2250 VAC
Performance
Response time (0...90%, 100...10%)< 30 ms / 300 ms (selectable)
AccuracyBetter than 0.05% of selected range
Signal/noise ratioMin. 60 dB
ProgrammingDIP switches
Signal dynamics, input23 bit
Signal dynamics, output18 bit
EMC immunity influence< ±0.5% of span
Extended EMC immunity< ±1% of span
Input Specifications
Temperature range, Pt100-200...+850°C
Min. measurement range (span)10°C
AccuracyBetter than 0.05% of span or 0.1°C
Temperature coefficient0.02°C/°C or ≤ ±0.01%/°C
Sensor current< 150 µA
Sensor cable resistance< 50 Ω per wire
Effect of sensor cable resistance (3-/4-wire)< 0.002 Ω / Ω
Sensor error detectionYes - selectable via DIP-switch
Broken sensor detection> 800 Ω
Shorted sensor detection< 18 Ω
Output Specifications
Current Output
Signal range0...23 mA
Programmable signal ranges0 / 4...20 mA
Sensor error indication (0...20 mA)0 mA or 23 mA / OFF
Sensor error indication (4...20 mA)3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF
Load (@ current output)≤ 600 Ω
Load stability≤ 0.01% of span / 100 Ω
Voltage Output
Programmable signal ranges0/1...5 and 0/2...10 V
Sensor error indication0 V / 10% above the max. / none
Safety Certifications & Approvals
ATEXII 3 G Ex ec IIC T4 Gc
IECExEx ec IIC T4 Gc
FM, USCl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CACl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
EAC Ex2Ex nA IIC T4 Gc X
Compliance & Standards
EMC2014/30/EU & UK SI 2016/1091
LVD2014/35/EU & UK SI 2016/1101
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approval Certificates
ATEXKEMA 10ATEX0147 X
IECExKEM 10.0068X
UKEXDEKRA 21UKEX0055X
c FM usFM17US0004X / FM17CA0003X
c UL us, UL 61010-1E314307
EAC ExEAEU KZ 7500361.01.01.08756