Xi'an Yingzhuoke Industrial Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Flow Measurement Instrument > NEW-CONSENS LDQ8 Retractable Insertion Electromagnetic Flowmeter DN200-DN2000 for Hot Tap Installation

NEW-CONSENS LDQ8 Retractable Insertion Electromagnetic Flowmeter DN200-DN2000 for Hot Tap Installation

Product Details

Place of Origin: Zhejiang, China

Brand Name: NEW-CONSENS

Certification: ISO 9001:2015, CE

Model Number: LDQ8

Payment & Shipping Terms

Minimum Order Quantity: 1 Set

Price: USD 520-1,980 / Set

Packaging Details: Rigid foam case with probe protection tube, export carton

Delivery Time: 10-15 working days, 18-25 days for high pressure versions

Payment Terms: T/T, L/C, Western Union

Supply Ability: 300 Sets per Month

Chat now
Highlight:

Retractable electromagnetic flowmeter DN200-DN2000

,

Hot tap insertion flowmeter

,

Electromagnetic flowmeter hot tap installation

Principle:
Faraday Electromagnetic Induction
Installation Type:
Insertion, Retractable Under Pressure
Accuracy:
±1.0% Of Reading
Probe Material:
316L Stainless Steel, Optional Hastelloy
Pressure Rating:
1.6 MPa Standard, 2.5 MPa Optional
Temperature Range:
-20 To 120 °C
Protection:
IP68 Probe, IP65 Converter
Communication:
4-20 MA, RS485 Modbus RTU, Pulse
Principle:
Faraday Electromagnetic Induction
Installation Type:
Insertion, Retractable Under Pressure
Accuracy:
±1.0% Of Reading
Probe Material:
316L Stainless Steel, Optional Hastelloy
Pressure Rating:
1.6 MPa Standard, 2.5 MPa Optional
Temperature Range:
-20 To 120 °C
Protection:
IP68 Probe, IP65 Converter
Communication:
4-20 MA, RS485 Modbus RTU, Pulse
NEW-CONSENS LDQ8 Retractable Insertion Electromagnetic Flowmeter DN200-DN2000 for Hot Tap Installation

NEW-CONSENS LDQ8 Retractable Insertion Electromagnetic Flowmeter – 2026 New Launch

New 2026 release: a retractable insertion electromagnetic flowmeter with a hot-tap ball valve, so large pipes can be metered without draining the line or stopping production.

Large transmission mains and cooling water headers are the hardest pipes to meter because nobody wants to cut them. The LDQ8 solves that with a retractable probe that is installed through a hot-tap ball valve while the line stays in service. The probe can be withdrawn, cleaned or recalibrated later without depressurising the pipeline, which turns a planned shutdown into a fifteen minute field job.

Why This New Launch Is Worth Switching To

  • Hot-tap installation under full line pressure removes the need for a shutdown, drain-down or pipe cut on DN200 to DN2000 mains.
  • Retractable probe can be pulled back through the valve for inspection and cleaning without breaking the seal.
  • Insertion design costs a fraction of a full-bore magnetic meter at large diameters while keeping ±1.0% accuracy.
  • One probe length covers a wide range of pipe sizes, which simplifies spare parts stock for multi-site operators.

Key Design Features

  • Balanced probe head with four measuring electrodes averages the velocity profile and reduces swirl error downstream of bends.
  • Integrated grounding electrode removes the need for separate grounding rings on most steel and ductile iron pipes.
  • Backlit LCD shows flow rate, totaliser, velocity and diagnostic codes for empty pipe and low conductivity.
  • Optional 2.5 MPa version for high pressure cooling water and process headers.

Technical Specifications

ParameterSpecification
PrincipleFaraday electromagnetic induction
Installation TypeInsertion, retractable under pressure
Accuracy±1.0% of reading
Probe Material316L stainless steel, optional Hastelloy
Pressure Rating1.6 MPa standard, 2.5 MPa optional
Temperature Range-20 to 120 °C
ProtectionIP68 probe, IP65 converter
Communication4-20 mA, RS485 Modbus RTU, pulse

Typical Applications

  • Municipal raw water and treated water transmission mains from DN600 to DN2000.
  • Cooling water headers in steel, chemical and power plants where shutdown windows are short.
  • Retrofit metering of existing large pipes with no spare straight length for a full-bore meter.

Ordering Information

ItemDetail
Minimum Order Quantity1 Set
Price RangeUSD 520-1,980 / Set
Payment TermsT/T, L/C, Western Union
Supply Ability300 Sets per Month
Delivery Time10-15 working days, 18-25 days for high pressure versions
PackagingRigid foam case with probe protection tube, export carton
Place of OriginZhejiang, China
CertificationISO 9001:2015, CE

Send us the pipe outside diameter, wall thickness, liner or cement lining details and normal flow rate, and we will confirm probe length, price and installation drawings within one working day.