Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Industrial Sensors‌ > PR 5331D Programmable Transmitter 1.5 kVAC Galvanic Isolation 0.05% Accuracy RTD TC Ohm mV Input

PR 5331D Programmable Transmitter 1.5 kVAC Galvanic Isolation 0.05% Accuracy RTD TC Ohm mV Input

Product Details

Place of Origin: Denmark

Brand Name: PR

Certification: CO

Model Number: PR 5331D

Document: Temperature-Transmitter-Puc...-0.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 73usd

Delivery Time: 5-7 work days

Payment Terms: T/T

Supply Ability: 99pcs 4-6 weeks

Chat now
Highlight:

PR 5331D Programmable Transmitter

,

RTD 2 Wire Transmitter

,

TC 2 Wire Transmitter

Operating Temperature:
-40°C To +85°C
Calibration Temperature:
20...28°C
Relative Humidity:
< 95% RH (non-cond.)
Protection Degree:
IP68 / IP00
Dimensions:
Ø 44 X 20.2 Mm
Weight:
50 G
Supply Voltage:
7.2...30 VDC
Isolation Voltage:
1.5 KVAC / 50 VAC
Operating Temperature:
-40°C To +85°C
Calibration Temperature:
20...28°C
Relative Humidity:
< 95% RH (non-cond.)
Protection Degree:
IP68 / IP00
Dimensions:
Ø 44 X 20.2 Mm
Weight:
50 G
Supply Voltage:
7.2...30 VDC
Isolation Voltage:
1.5 KVAC / 50 VAC
PR 5331D Programmable Transmitter 1.5 kVAC Galvanic Isolation 0.05% Accuracy RTD TC Ohm mV Input
2-Wire Programmable Transmitter PR 5331D

Advanced programmable transmitter supporting RTD, TC, Ohm, or mV input with exceptional measurement accuracy and 1.5 kVAC galvanic isolation. Designed for DIN form B sensor head mounting with programmable sensor error detection.

Key Features
  • Extremely high measurement accuracy (better than 0.05% of selected range)
  • 1.5 kVAC galvanic isolation for enhanced safety
  • Programmable sensor error value detection
  • DIN form B sensor head mount compatibility
  • Wide operating temperature range: -40°C to +85°C
  • Multiple input types: RTD, thermocouple, linear resistance, and voltage
Environmental Conditions
Operating temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degree (enclosure/terminal)IP68 / IP00
Mechanical Specifications
DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm² stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6 compliant
Electrical Specifications
Power Supply
Supply voltage7.2...30 VDC
Internal power dissipation25 mW…0.7 W
Voltage drop7.2 VDC
Isolation & Response
Isolation voltage, test / working1.5 kVAC / 50 VAC
Response time (programmable)1...60 s
Warm-up time5 min.
Power on to stable output4.5 s
Performance
AccuracyBetter than 0.05% of selected range
Signal dynamics, input20 bit
Signal dynamics, output16 bit
Effect of supply voltage change< 0.005% of span / VDC
EMC immunity influence< ±0.5% of span
Input Specifications
RTD Input
RTD typePt100, Ni100, linear R
Cable resistance per wire5 Ω (max.)
Sensor currentNom. 0.2 mA
Sensor error detectionYes
Thermocouple Input
Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC)< ±1.0°C
Sensor error detectionYes
Voltage Input
Measurement range-12...800 mV
Min. measurement range (span)5 mV
Input resistance10 MΩ
Output Specifications
Signal range4…20 mA
Min. signal range16 mA
Load stability≤ 0.01% of span / 100 Ω
Updating time440 ms
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Certifications & Approvals
Intrinsic Safety Certifications
ATEXII 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma
IECExEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
FM, USCl. I, Div. 1, Gp. A, B, C, D T4/T6; Cl. I Zone 0, AEx ia IIC T4/T6
CSACl. I, Div. 1, Gp. A, B, C, D Ex ia IIC, Ga
INMETROEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
Approval Numbers
ATEXDEKRA 20ATEX0095X
IECExDEK 20.0059X
FMFM17US0013X
CSA1125003
INMETRODEKRA 23.0009X
DNV MarineTAA0000101
EAC ExEAEU KZ 7500361.01.01.08756
Compliance Standards
EMC2014/30/EU
ATEX2014/34/EU
RoHS2011/65/EU
EACTR-CU 020/2011
EAC ExTR-CU 012/2011