Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Industrial Sensors‌ > Field Mounted HART Temperature Transmitters PR 7501 With High Definition LOI Selectable Backlight

Field Mounted HART Temperature Transmitters PR 7501 With High Definition LOI Selectable Backlight

Product Details

Place of Origin: Denmark

Brand Name: PR

Certification: CO

Model Number: PR 7501

Document: 7501v110_uk.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: usd435

Delivery Time: 5-7 work days

Payment Terms: T/T

Supply Ability: 99PCS 4-6 WEEKS

Chat now
Highlight:

HART Temperature Transmitters

,

Field Mounted Temperature Transmitters

Application:
Industrial Process Control, HVAC, Hydraulic Systems
Accuracy:
±0.25% Of Full Scale
Measurementrange:
0 To 1000 Psi
Outputsignal:
4-20 MA, 0-10 V
Pressuretype:
Gauge, Absolute, Differential
Responsetime:
≤1 Second
Operatingtemperature:
-20°C To 80°C
Connectiontype:
1/4 Inch NPT
Displaytype:
Digital LCD
Powersupply:
24 V DC
Material:
Stainless Steel
Protectionrating:
IP65
Productname:
Pressure Measurement Instruments
Mountingoptions:
Panel, Wall, Pipe
Application:
Industrial Process Control, HVAC, Hydraulic Systems
Accuracy:
±0.25% Of Full Scale
Measurementrange:
0 To 1000 Psi
Outputsignal:
4-20 MA, 0-10 V
Pressuretype:
Gauge, Absolute, Differential
Responsetime:
≤1 Second
Operatingtemperature:
-20°C To 80°C
Connectiontype:
1/4 Inch NPT
Displaytype:
Digital LCD
Powersupply:
24 V DC
Material:
Stainless Steel
Protectionrating:
IP65
Productname:
Pressure Measurement Instruments
Mountingoptions:
Panel, Wall, Pipe
Field Mounted HART Temperature Transmitters PR 7501 With High Definition LOI Selectable Backlight
Field Mounted HART Temperature Transmitter
Model: PR 7501
Product Overview
  • RTD, TC, Ohm, and bipolar mV input with analog output
  • High definition local operator interface (LOI) with 3 optical buttons
  • Selectable red or white backlight display
Environmental Conditions
Operating temperature-40°C to +85°C (with silicone O-ring)
-20°C to +85°C (with FKM O-ring)
Storage temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity0...100% RH (condensing)
Protection degreeIP54 / IP66 / IP68 / type 4X
Corrosion class 7501AxxxBxxxx / durabilityC5-I/M / 5...15 years
Mechanical Specifications
DimensionsØ 110 mm
Dimensions (HxWxD), aluminum109.3 x 145 x 126 mm
Dimensions (HxWxD), stainless steel107.4 x 145 x 124 mm
Weight approx., aluminum / stainless steel1.3 / 2.8 kg
Wire size0.13 x 1.5 mm² / AWG 26...16 stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6
2...25 Hz: ±1.6 mm
25...100 Hz: ±4 g
Display resolution96 x 64 pixels
Number of digits5
BacklightSelectable ON/OFF
Backlight colorSelectable white or red
Common Specifications
Supply
Supply voltage, DC: Ex ia, intrinsically safe10 (12 - with backlight)...30 VDC
Supply voltage, DC: Other10 (12 - with backlight)...35 VDC
Isolation Voltage
Isolation voltage, test / working1.5 kVAC / 50 VAC
Response Time
Response time (programmable)1...60 s
Signal / noise ratio> 60 dB
ProgrammingHART
Start-up time, transmitter to displayMax. 5 s
Long-term stability, better than±0.1% of span / year
AccuracyBetter than 0.05% of selected range
Signal dynamics, input22 bit
Signal dynamics, output16 bit
EMC immunity influence< ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span
Input Specifications
Common Input Specifications
Max. offset50% of selected max. value
RTD Input
RTD typePt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor currentNom. 0.2 mA
Linear Resistance Input
Linear resistance min....max.0 Ω...7000 Ω
TC Input
Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC)Constant, internal or external via a Pt100 or Ni100 sensor
Voltage Input
Measurement range-800...+800 mV
Min. measurement range (span)2.5 mV
Input resistance10 MΩ
Output Specifications
Current Output
Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply - 10) / 0.023 [Ω]
Load resistance, with backlight≤ (Vsupply - 12) / 0.023 [Ω]
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Common Output Specifications
Updating time440 ms
HART protocol revisionsHART 7 and HART 5
Compliance & Certifications
EMC2014/30/EU & UK SI 2016/1091
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approvals
ATEXDEKRA 15ATEX0058X
IECExIECEx DEK 15.0039 X
c FM usFM16US0009X / FM16CA0010X
CSA70024231
INMETRODEKRA 23.0012 X
NEPSIGYJ20.1630X
EU RO MR Type ApprovalMRA0000009
EAC ExEAEU KZ 7500361.01.01.08756
SILHardware assessed for use in SIL applications