Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Products
Products
Home > Products > Industrial Sensors‌ > PR 6337A Temperature Transmitters HART 7 Protocol For RTD TC Signals In DIN Rail Mounting

PR 6337A Temperature Transmitters HART 7 Protocol For RTD TC Signals In DIN Rail Mounting

Product Details

Place of Origin: Denmark

Brand Name: PR

Certification: CO

Model Number: PR 6337A

Document: 6337v103_uk.pdf

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 150

Delivery Time: 5-7 work days

Payment Terms: T/T

Supply Ability: 99pcs 4-6 weeks

Chat now
Highlight:

PR 6337A Temperature Transmitters

,

Temperature Transmitters HART 7 Protocol

PR 6337A Temperature Transmitters HART 7 Protocol For RTD TC Signals In DIN Rail Mounting
2-Wire HART Transmitter PR 6337A
1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals with 2 analogue inputs and 5 device variables with status available. HART protocol revision selectable.
Environmental Conditions
Operating temperature -40°C to +85°C
Storage temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-condensing)
Protection degree IP20
Mechanical Specifications
Dimensions (HxWxD) 109 x 23.5 x 104 mm
Weight (1 / 2 channels) 150 / 200 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm² AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm
Common Specifications
Supply
Supply voltage 8.0...35 VDC
Internal power dissipation, 1 / 2 ch. 19 mW...0.8 / 1.6 W
Isolation Voltage
Isolation voltage, test / working 1.5 kVAC / 50 VAC
Response Time & Performance
Response time (programmable) 1...60 s
Voltage drop 8.0 VDC
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Signal / noise ratio > 60 dB
Accuracy Better than 0.05% of selected range
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
Input Specifications
Common Input Specifications
Max. offset 50% of selected max. value
RTD Input
RTD type Pt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor current Nom. 0.2 mA
Linear Resistance Input
Linear resistance min....max. 0 Ω...7000 Ω
TC Input
Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC) Constant, internal or external via a Pt100 or Ni100 sensor
Voltage Input
Measurement range -800...+800 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Output Specifications
Current Output
Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
Common Output Specifications
Updating time 440 ms
HART protocol revisions HART 7 and HART 5
Compliance & Standards
EMC 2014/30/EU & UK SI 2016/1091
ATEX 2014/34/EU & UK SI 2016/1107
RoHS 2011/65/EU & UK SI 2012/3032
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Approvals & Certifications
ATEX DEKRA 20ATEX0109X
IECEx DEK 20.0063X
CSA 1125003
INMETRO DEKRA 23.0011X
EAC Ex EAEU KZ 7500361.01.01.08756
SIL Hardware assessed for use in SIL applications