Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
Produk
Produk
Rumah > Produk > Pressure Measurement Instruments‌ > MDM4901FL Fluorinated Oil Filled High Precision IP65 Differential Pressure Transmitter Oxygen Measurement

MDM4901FL Fluorinated Oil Filled High Precision IP65 Differential Pressure Transmitter Oxygen Measurement

Rincian produk

Tempat asal: Cina

Sertifikasi: CO

Nomor model: MDM4901FL

Dokumen: mdm4901fl-differential-pres...rs.pdf

Syarat Pembayaran & Pengiriman

Kuantitas min Order: 1

Harga: 10-100usd

Waktu pengiriman: 5-7 hari kerja

Syarat-syarat pembayaran: T/T

Menyediakan kemampuan: 99pcs 1-2 minggu

bicara sekarang
Menyoroti:

oxygen differential pressure transmitter

,

fluorinated oil pressure transmitter

,

high precision oxygen transmitter

ResponseTime:
≤ 1 ms
Tipe tekanan:
Pengukur, Mutlak, Diferensial
Bahan:
Baja Tahan Karat
Nama Produk:
Instrumen Pengukuran Tekanan
Aplikasi:
Kontrol proses industri, HVAC, sistem hidrolik
Peringkat perlindungan:
IP65
Ketepatan:
±0,25% FS
Catu daya:
24 V DC
Kalibrasi:
Dikalibrasi Pabrik
Jenis koneksi:
NPT 1/4 inci
Tipe tampilan:
LCD digital
Opsi pemasangan:
Pemasangan panel, Pemasangan pipa
Suhu pengoperasian:
-20°C hingga 85°C
Jangkauan pengukuran:
0 hingga 1000 psi
Sinyal Keluaran:
4-20 ma
ResponseTime:
≤ 1 ms
Tipe tekanan:
Pengukur, Mutlak, Diferensial
Bahan:
Baja Tahan Karat
Nama Produk:
Instrumen Pengukuran Tekanan
Aplikasi:
Kontrol proses industri, HVAC, sistem hidrolik
Peringkat perlindungan:
IP65
Ketepatan:
±0,25% FS
Catu daya:
24 V DC
Kalibrasi:
Dikalibrasi Pabrik
Jenis koneksi:
NPT 1/4 inci
Tipe tampilan:
LCD digital
Opsi pemasangan:
Pemasangan panel, Pemasangan pipa
Suhu pengoperasian:
-20°C hingga 85°C
Jangkauan pengukuran:
0 hingga 1000 psi
Sinyal Keluaran:
4-20 ma
MDM4901FL Fluorinated Oil Filled High Precision IP65 Differential Pressure Transmitter Oxygen Measurement
MDM4901FL Differential Pressure Transmitter for Oxygen Measurement
Specialized differential pressure transmitter filled with fluorinated oil internally, offering high precision, stability, and superior safety levels for oxygen measurement applications.
Performance Specifications
Measurement Range 0 kPa to 40 kPa... 3.5 MPa
Overload Pressure Positive pressure end ≤ 2 times full range pressure
Negative pressure end does not allow overpressure
Maximum Static Pressure ≤ 20 MPa
Pressure Type Differential pressure type
Accuracy Details Available in measurement range and accuracy table
Technical Specifications
Long-term Stability ± 0.5% FS/year (≤ 200 kPa)
± 0.2% FS/year (> 200 kPa)
Operating Temperature -30 ℃ to 80 ℃ (B1, B11)
-20 ℃ to 70 ℃ (B2, cable material: polyethylene)
-20 ℃ to 80 ℃ (B2, cable material: polyurethane)
Storage Temperature -40 ℃ to 120 ℃ (B1, B11)
-20 ℃ to 85 ℃ (B2)
Vibration Resistance 10g, 30 Hz to 2000 Hz
Impact Resistance 100g, 11 ms
Protection Level IP65
Weight ≤ 400 g