Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
productos
productos
Hogar > productos > Industrial Sensors‌ > 2 Wire HART Transmitter PR 5335D With 0.05% Accuracy HART 5 Protocol And Galvanic Isolation

2 Wire HART Transmitter PR 5335D With 0.05% Accuracy HART 5 Protocol And Galvanic Isolation

Detalles del producto

Lugar de origen: En el caso de los Estados miembros:

Nombre de la marca: PR

Certificación: CO

Número de modelo: PR 5335

Documento: 5335v118_uk.pdf

Pago y términos de envío

Cantidad de orden mínima: 1

Precio: 87

Tiempo de entrega: 5-7 días laborables

Condiciones de pago: T/T

Capacidad de la fuente: 99 piezas 4-6 semanas

Resaltar:

0.05% Accuracy Temperature Transmitter

,

HART 5 Protocol 2 wire Transmitter

,

Galvanic Isolation HART Transmitter

Plazo de entrega estimado:
en stock
Rango de voltaje de funcionamiento:
4.5 V de corriente continua... 32 V de corriente continua
Código HS:
8538909100
Tipo:
El sistema de control de las emisiones de gases de efecto invernadero se utiliza para controlar la e
Tipo de actuador:
Rotación lateral - sin palanca
tiempo de espera:
Negociable
Conexión eléctrica:
Terminal de tornillo
Número de pieza:
1037778
Tamaño de tubería:
G1/4
Producción:
4-20mA
Código de tarifa:
853650800
Voltaje:
230 V CA, 24 V CC
Origen:
Reino Unido
Temperatura de almacenamiento:
-40 a 70 °C (-40 a 158 °F)
Canal:
8 canales
Plazo de entrega estimado:
en stock
Rango de voltaje de funcionamiento:
4.5 V de corriente continua... 32 V de corriente continua
Código HS:
8538909100
Tipo:
El sistema de control de las emisiones de gases de efecto invernadero se utiliza para controlar la e
Tipo de actuador:
Rotación lateral - sin palanca
tiempo de espera:
Negociable
Conexión eléctrica:
Terminal de tornillo
Número de pieza:
1037778
Tamaño de tubería:
G1/4
Producción:
4-20mA
Código de tarifa:
853650800
Voltaje:
230 V CA, 24 V CC
Origen:
Reino Unido
Temperatura de almacenamiento:
-40 a 70 °C (-40 a 158 °F)
Canal:
8 canales
2 Wire HART Transmitter PR 5335D With 0.05% Accuracy HART 5 Protocol And Galvanic Isolation
2-Wire HART Transmitter PR 5335DRTD
Product Overview
  • 2-wire transmitter with HART 5 protocol
  • TC, Ohm, or mV input compatibility
  • Extremely high measurement accuracy
  • Galvanic isolation
  • Designed for DIN form B sensor head mounting
Environmental Conditions
Operating temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degree (enclosure/terminal)IP68 / IP00
Mechanical Specifications
DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm² stranded wire
Screw terminal torque0.4 Nm
Vibration (IEC 60068-2-6)2...25 Hz: ±1.6 mm
25...100 Hz: ±4 g
Common Specifications
Supply voltage8.0...30 VDC
Isolation voltage (test/working)1.5 kVAC / 50 VAC
Response time (programmable)1...60 s
Warm-up time30 s
ProgrammingHART & PR 5909 Loop Link communications interface
Signal / noise ratio> 60 dB
AccuracyBetter than 0.05% of selected range
Signal dynamics, input22 bit
Signal dynamics, output16 bit
Effect of supply voltage change< 0.005% of span / VDC
EMC immunity influence< ±0.1% of span
Extended EMC immunity (NAMUR NE21)< ±1% of span
Input Specifications
Common Input Specifications
Maximum offset50% of selected maximum value
RTD Input
RTD typePt100, Ni100, linear R
Cable resistance per wire5 Ω (up to 50 Ω per wire possible with reduced accuracy)
Sensor currentNominal 0.2 mA
Effect of sensor cable resistance (3-/4-wire)< 0.002 Ω / Ω
Sensor error detectionYes
TC Input
Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC)< ±1.0°C
Sensor error detectionYes
Sensor error current (when detecting/else)Nominal 33 μA / 0 μA
Voltage Input
Measurement range-800...+800 mV
Minimum measurement range (span)2.5 mV
Input resistance10 MΩ
Output Specifications
Signal range4…20 mA
Minimum signal range16 mA
Load (@ current output)≤ (Vsupply - 8) / 0.023 [Ω]
Load stability≤ 0.01% of span / 100 Ω
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Intrinsic Safety & Explosion Protection Marking
ATEXII 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma
IECExEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
FM, USCl. I, Div. 1, Gp. A, B, C, D T4/T6; Cl. I Zone 0, AEx ia IIC T4/T6; Cl. 1, Div. 2, Gp. A, B, C, D, T4/T6
CSACl. I, Div. 1, Gp. A, B, C, D Ex ia IIC, Ga
INMETROEx ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma
Compliance with Authority Requirements
EMC2014/30/EU
ATEX2014/34/EU
RoHS2011/65/EU
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approvals and Certifications
ATEXDEKRA 20ATEX0108X
IECExDEK 20.0063X
FMFM17US0013X
CSA1125003
INMETRODEKRA 23.0011X
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA0000101
SILHardware assessed for use in SIL applications