Product Details
Place of Origin: China
Brand Name: HONEYWELL
Certification: CO certificate, CE optional
Model Number: STG79S-E1G000-1-C-CHS-14C-B-00A6-FX,F1,F5,FE,TP-0000
Payment & Shipping Terms
Minimum Order Quantity: 1 Piece
Price: USD 480-720 / Piece
Packaging Details: Factory-sealed Honeywell carton with foam insert, export double-wall carton, shipping weight about 10 kg
Delivery Time: 3-5 working days for stock, 4-6 weeks for factory order
Payment Terms: T/T, L/C at sight
Supply Ability: 400 Pieces per Month
|
Measurement Type:
|
Gauge Pressure, In-line
|
Reference Accuracy:
|
+/-0.0375% Of Calibrated Span
|
Output Signal:
|
4-20 MA Dc With HART Protocol
|
Wetted Materials:
|
316L Stainless Steel Diaphragm, 316 Stainless Steel Body
|
Measurement Range:
|
0-35 KPa Up To 0-21 MPa
|
Turndown Ratio:
|
Up To 100:1
|
Long-Term Stability:
|
+/-0.02% URL Per Year
|
Response Time:
|
Under 200 Ms
|
Housing:
|
Aluminum Housing, IP66/IP67
|
Process Connection:
|
1/2 In NPT Female
|
Warranty:
|
12 Months Factory Warranty
|
|
Measurement Type:
|
Gauge Pressure, In-line
|
|
Reference Accuracy:
|
+/-0.0375% Of Calibrated Span
|
|
Output Signal:
|
4-20 MA Dc With HART Protocol
|
|
Wetted Materials:
|
316L Stainless Steel Diaphragm, 316 Stainless Steel Body
|
|
Measurement Range:
|
0-35 KPa Up To 0-21 MPa
|
|
Turndown Ratio:
|
Up To 100:1
|
|
Long-Term Stability:
|
+/-0.02% URL Per Year
|
|
Response Time:
|
Under 200 Ms
|
|
Housing:
|
Aluminum Housing, IP66/IP67
|
|
Process Connection:
|
1/2 In NPT Female
|
|
Warranty:
|
12 Months Factory Warranty
|
When a gauge loop has to resolve small pressure changes on top of a large static head, standard 0.1% instruments simply cannot separate signal from noise. The Honeywell STG79S closes that gap with +/-0.0375% reference accuracy and up to 100:1 turndown, letting a single transmitter cover a wide range without sacrificing resolution at the bottom of the span.
Model: STG79S-E1G000-1-C-CHS-14C-B-00A6-FX,F1,F5,FE,TP-0000. New and original in factory packaging, 12 months factory warranty.
| Parameter | Specification |
|---|---|
| Reference accuracy | +/-0.0375% of calibrated span |
| Turndown ratio | Up to 100:1 |
| Output signal | 4-20 mA dc, HART protocol |
| Measurement range | 0-35 kPa up to 0-21 MPa |
| Response time | Under 200 ms |
| Wetted materials | 316L diaphragm, 316 stainless steel body |
| Process connection | 1/2 in NPT female |
| Enclosure | Aluminum housing, IP66/IP67 |
MOQ 1 piece, T/T payment, CO certificate included. Tell us the range and turndown you need and we will confirm the correct model code plus the fastest shipping option.