Product Details
Place of Origin: China
Brand Name: WinSMART
Certification: ISO 9001:2015, CE, RoHS
Model Number: LY50-O
Payment & Shipping Terms
Minimum Order Quantity: 1 Piece
Price: USD 258-540 / Piece
Packaging Details: Sealed oxygen service bag with certificate pack, then foam-lined export carton
Delivery Time: 10-15 working days for stock, 20-30 days for production
Payment Terms: T/T, L/C, Western Union, PayPal
Supply Ability: 1500 Pieces per Month
|
Reference Accuracy:
|
+/-0.05% Of Span
|
Measuring Range:
|
0-10 KPa To 0-40 MPa
|
Cleaning Standard:
|
ASTM G93 Oil Free
|
Wetted Parts:
|
Hastelloy C-276 Diaphragm
|
Fill Fluid:
|
Inert Fluorinated Oil Or Dry Cell
|
Housing Material:
|
316L Stainless Steel
|
Enclosure:
|
IP67
|
Output Signal:
|
4-20 MA + HART 7
|
Process Temperature:
|
-20 To +120 C
|
Residue Limit:
|
< 100 Mg/m2 Hydrocarbon
|
Nameplate:
|
Stainless Steel
|
|
Reference Accuracy:
|
+/-0.05% Of Span
|
|
Measuring Range:
|
0-10 KPa To 0-40 MPa
|
|
Cleaning Standard:
|
ASTM G93 Oil Free
|
|
Wetted Parts:
|
Hastelloy C-276 Diaphragm
|
|
Fill Fluid:
|
Inert Fluorinated Oil Or Dry Cell
|
|
Housing Material:
|
316L Stainless Steel
|
|
Enclosure:
|
IP67
|
|
Output Signal:
|
4-20 MA + HART 7
|
|
Process Temperature:
|
-20 To +120 C
|
|
Residue Limit:
|
< 100 Mg/m2 Hydrocarbon
|
|
Nameplate:
|
Stainless Steel
|
The LY50-O is prepared for oxygen and other oxidising gases where any hydrocarbon residue is a hazard. Every unit is degreased and cleaned to ASTM G93, assembled with oxygen-compatible seals and filled with inert fill fluid, while the diaphragm is Hastelloy C-276 and the accuracy reaches ±0.05% of span instead of the ±0.1% common in previous cleaned transmitters.
| Item | Previous Generation | LY50 Upgrade |
|---|---|---|
| Wetted parts | 316L stainless steel | Hastelloy C-276 (UNS N10276) |
| Reference accuracy | ±0.075% of span | ±0.05% of span |
| Housing | Die-cast aluminium | 316L stainless steel housing |
| Long-term stability | ±0.1% of URL per 5 years | ±0.05% of URL per 5 years |
| Nameplate | Plastic label | Laser-engraved stainless steel plate |
| Reference accuracy | ±0.05% of span |
| Measuring range | 0–10 kPa to 0–40 MPa |
| Cleaning standard | ASTM G93, oil free |
| Wetted parts | Hastelloy C-276 diaphragm |
| Fill fluid | Inert fluorinated oil or dry cell |
| Housing | 316L stainless steel |
| Enclosure | IP67 |
| Output signal | 4–20 mA + HART 7 |
| Process temperature | -20°C to +120°C |
| Residue limit | < 100 mg/m² hydrocarbon |
Each transmitter is delivered in a sealed bag with an oxygen service certificate, residue test record and calibration certificate. Cleaning records are retained for five years for audit purposes.