Product Details
Place of Origin: China
Brand Name: WinSMART
Certification: ISO 9001:2015, ATEX, IECEx, CE
Model Number: LY50-EX
Payment & Shipping Terms
Minimum Order Quantity: 1 Piece
Price: USD 268-560 / Piece
Packaging Details: Flameproof housing with protective cap, certificate pack in moisture barrier bag, export carton
Delivery Time: 10-15 working days for stock, 20-30 days for production
Payment Terms: T/T, L/C, Western Union, PayPal
Supply Ability: 1500 Pieces per Month
|
Ex Marking:
|
Ex D IIC T6 Gb
|
Certification:
|
ATEX, IECEx
|
Reference Accuracy:
|
+/-0.05% Of Span
|
Measuring Range:
|
0-10 KPa To 0-60 MPa
|
Housing Material:
|
316L Stainless Steel Flameproof
|
Enclosure:
|
IP68
|
Output Signal:
|
4-20 MA + HART 7
|
Ambient Temperature:
|
-40 To +85 C
|
Process Temperature:
|
-40 To +125 C
|
Cable Entry:
|
M20x1.5 Or 1/2 NPT
|
Nameplate:
|
Stainless Steel
|
|
Ex Marking:
|
Ex D IIC T6 Gb
|
|
Certification:
|
ATEX, IECEx
|
|
Reference Accuracy:
|
+/-0.05% Of Span
|
|
Measuring Range:
|
0-10 KPa To 0-60 MPa
|
|
Housing Material:
|
316L Stainless Steel Flameproof
|
|
Enclosure:
|
IP68
|
|
Output Signal:
|
4-20 MA + HART 7
|
|
Ambient Temperature:
|
-40 To +85 C
|
|
Process Temperature:
|
-40 To +125 C
|
|
Cable Entry:
|
M20x1.5 Or 1/2 NPT
|
|
Nameplate:
|
Stainless Steel
|
The LY50-EX packages the LY50 measuring core in a flameproof 316L stainless steel enclosure rated Ex d IIC T6 Gb and IP68. The previous generation relied on an aluminium housing with a separate barrier; the LY50 design integrates the flameproof path into a corrosion-resistant stainless body, while reference accuracy improves from ±0.075% to ±0.05% of span.
| Item | Previous Generation | LY50 Upgrade |
|---|---|---|
| Wetted parts | 316L stainless steel | Hastelloy C-276 (UNS N10276) |
| Reference accuracy | ±0.075% of span | ±0.05% of span |
| Housing | Die-cast aluminium | 316L stainless steel housing |
| Long-term stability | ±0.1% of URL per 5 years | ±0.05% of URL per 5 years |
| Nameplate | Plastic label | Laser-engraved stainless steel plate |
| Ex marking | Ex d IIC T6 Gb / Ex ia IIC T6 Ga |
| Certification | ATEX, IECEx |
| Reference accuracy | ±0.05% of span |
| Measuring range | 0–10 kPa to 0–60 MPa |
| Housing | 316L stainless steel, flameproof |
| Enclosure | IP68 |
| Output signal | 4–20 mA + HART 7 |
| Ambient temperature | -40°C to +85°C |
| Process temperature | -40°C to +125°C |
| Cable entry | M20 x 1.5 or 1/2 in NPT |
Certificates of conformity, ATEX and IECEx documentation and the Ex nameplate data are supplied with every unit. Junction boxes and certified cable glands for Zone 1 installation can be quoted as a set.