Product Details
Place of Origin: China
Brand Name: CAF
Certification: ISO 9001:2015, CE
Model Number: WQA-5600C
Payment & Shipping Terms
Minimum Order Quantity: 1 Piece
Price: USD 899-1199 / Piece
Packaging Details: Foam-lined export carton with stainless fittings bag and installation manual
Delivery Time: 10-20 working days after payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 400 Pieces per Month
|
Measurement Parameters:
|
PH, ORP, Conductivity, Turbidity, Residual Chlorine, DO, Temperature
|
PH Accuracy:
|
Plus Or Minus 0.01 PH
|
Conductivity Accuracy:
|
Plus Or Minus 0.5% FS
|
Long Term Drift:
|
Below 0.2% Per 24 Hours
|
Refresh Interval:
|
5 Seconds
|
Output Signal:
|
4-20 MA, RS485 Modbus RTU, Two Relays, Optional HART
|
Flow Cell Material:
|
316L Stainless Steel With PVDF Body
|
Electrode Junction:
|
Ceramic Double Junction
|
Housing Protection:
|
IP66
|
Power Supply:
|
24 V DC, Optional 220 V AC
|
Sample Temperature:
|
Up To 80 Degrees Celsius
|
Mounting:
|
Wall, Panel Or Pipe Mount
|
Data Logging:
|
30 Day Rolling Log With SD Card Export
|
Warranty:
|
24 Months
|
|
Measurement Parameters:
|
PH, ORP, Conductivity, Turbidity, Residual Chlorine, DO, Temperature
|
|
PH Accuracy:
|
Plus Or Minus 0.01 PH
|
|
Conductivity Accuracy:
|
Plus Or Minus 0.5% FS
|
|
Long Term Drift:
|
Below 0.2% Per 24 Hours
|
|
Refresh Interval:
|
5 Seconds
|
|
Output Signal:
|
4-20 MA, RS485 Modbus RTU, Two Relays, Optional HART
|
|
Flow Cell Material:
|
316L Stainless Steel With PVDF Body
|
|
Electrode Junction:
|
Ceramic Double Junction
|
|
Housing Protection:
|
IP66
|
|
Power Supply:
|
24 V DC, Optional 220 V AC
|
|
Sample Temperature:
|
Up To 80 Degrees Celsius
|
|
Mounting:
|
Wall, Panel Or Pipe Mount
|
|
Data Logging:
|
30 Day Rolling Log With SD Card Export
|
|
Warranty:
|
24 Months
|
The WQA-5600C is a continuous online multi parameter water quality analyzer for plant rooms, pump stations and treatment lines that run around the clock. This upgraded model answers the three issues operators reported most often with the previous series: readings that drifted between calibrations, wet cells that corroded in chlorinated water, and controllers that were difficult to integrate with existing SCADA systems.
| Parameter | Specification |
|---|---|
| Model | WQA-5600C |
| Measurement parameters | pH, ORP, conductivity, turbidity, residual chlorine, dissolved oxygen, temperature |
| pH accuracy | plus or minus 0.01 pH |
| Conductivity accuracy | plus or minus 0.5% FS |
| Long term drift | Below 0.2% per 24 hours (previous generation: 0.5% per 24 hours) |
| Refresh interval | 5 seconds, continuous operation |
| Output | 4-20 mA, RS485 Modbus RTU, two relay outputs, optional HART |
| Flow cell material | 316L stainless steel with PVDF body |
| Electrode junction | Ceramic double junction |
| Housing protection | IP66 control enclosure |
| Power supply | 24 V DC, optional 220 V AC |
| Operating temperature | 0 to 60 degrees Celsius, sample up to 80 degrees Celsius |
| Mounting | Wall mount, panel mount or pipe mount |
| Data logging | Internal 30 day rolling log with SD card export |
The analyzer is supplied with a stainless steel flow cell, sample inlet and outlet fittings, a pressure regulator recommendation sheet and a wiring diagram for Modbus and relay connections. Optional accessories include a sample conditioning filter, a bypass manifold and a weather shield for outdoor installation.
Standard configuration includes the analyzer main unit, sensor set, calibration solutions, USB cable and operation manual. Custom probe lengths, extra parameters, local language interfaces and OEM branding are available on request. Our technical team supports method setup, calibration training and after-sales spare parts supply.
Contact our sales team for a quotation, datasheet or sample evaluation unit.