Product Details

Place of Origin: Japan

Brand Name: HIOKI

Certification: CO

Model Number: HIOKI Power Quality Analyzer PQ3100

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 6960-8500USD

Packaging Details: Standard cardboard box packaging

Delivery Time: 6-8weeks

Payment Terms: T/T

Supply Ability: 99pcs/6-8weeks

Chat now
Highlight:

HIOKI PQ3100 power quality analyzer

,

compact lightweight power analyzer

,

single-phase three-phase clamp meter

Outputsignal:
4-20 MA, 0-10 V, Digital
Operatingtemperature:
-20°C To 85°C
Application:
Industrial, HVAC, Automotive
Measurementrange:
0 To 1000 Psi
Productname:
Pressure Measurement Instruments
Outputinterface:
RS485, HART, Modbus
Pressurerange:
0 To 10000 Psi
Applications:
Industrial, HVAC, Automotive, Oil & Gas
Accuracy:
±0.5% Of Full Scale
Powersupply:
24 V DC
Outputsignal:
4-20 MA, 0-10 V, Digital
Operatingtemperature:
-20°C To 85°C
Application:
Industrial, HVAC, Automotive
Measurementrange:
0 To 1000 Psi
Productname:
Pressure Measurement Instruments
Outputinterface:
RS485, HART, Modbus
Pressurerange:
0 To 10000 Psi
Applications:
Industrial, HVAC, Automotive, Oil & Gas
Accuracy:
±0.5% Of Full Scale
Powersupply:
24 V DC
HIOKI Power Quality Analyzer PQ3100 Single-phase 2-wire ~ Three-phase 4-wire Clamp Input Compact And Lightweight
  • All voltage, current, power, harmonics, flicker, etc. are measured simultaneously in sequence (Ver.UP includes flicker function)
  • Trend recording captures all power anomalies such as instant power outages, voltage drops, frequency changes
  • Easily master measurement steps with QUICK SET function
  • Accessory application software PQ ONE can generate reports compliant with GB standards
  • Can record waveforms for up to 1 second before and 10 seconds after an event
  • Can accurately measure DC current over a long period (using AC/DC automatic zeroing current sensor)
  • The current sensor is powered by the PQ3100 main unit
Basic parameters (accuracy guarantee period of 1 year, accuracy warranty after adjustment 1 year)
Measuring the route In addition to single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire, CH4 can also be used to measure voltage/current (all channels can be measured with AC/DC).
Voltage range Voltage measurement is 1000.0 Vrms or DC, transient measurement is 2.200 kVpeak
Current travel range AC/DC 50.000 mA~5.0000 kA (varies depending on the measurement range of the sensor used)
Power range 50,000 W~6,0000 MW (automatically determined based on the current range and wiring used)
Basic accuracy Voltage: ±0.2% of nominal voltage, current: ±0.1% rdg. ±0.1% f.s. + current sensor accuracy
AC ±0.2% rdg. ± 0.1% f.s. + current sensor accuracy
Measurement function
  1. Transient overvoltage: 200 kHz sampling
  2. Frequency 1 wave: Calculate from a single waveform
  3. Voltage 1/2 RMS value, current 1/2 RMS value: Calculate one waveform every half wavelength interval
  4. Surge, subsidence, power outage: Detect when voltage is 1/2 RMS value
  5. Impulse current: Detects the RMS value after calculating the current after each half-wave
  6. Frequency 200 ms: Calculate from 10 waveforms and 12 waveforms
  7. Frequency of 10 seconds: Calculate from waveforms within 10 seconds
  8. Voltage waveform peak, current waveform peak
  9. Voltage, current, active power, apparent power, reactive power, active energy, apparent electrical energy, reactive energy, electricity cost, power factor, displacement power factor, voltage unbalance rate, current unbalance rate
  10. Voltage crest factor, current crest factor
  11. Harmonics/phase angle (voltage/current), harmonic power: 0th ~ 50th
  12. Harmonic voltage and current phase difference: 1st ~ 50th order
  13. Total harmonic distortion rate (voltage/current)
  14. Interharmonics (voltage/current): 0.5th order ~ 49.5th order
  15. K-factor (multiplication rate)
  16. (Ver.UP) Transient flicker value: Complies with IEC61000-4-15
  17. (Ver.UP) ΔV10 flicker, IEC flicker (short-term/long-duration)
The longest recorded time Longest 1 year, highest recorded duration: 9,999 cases * 365 days
Interface SD/SDHC memory card, RS-232C, LAN (HTTP server function), USB 2.0
Display 6.5-inch TFT color LCD (640 * 480 pixels)
Power supply AC adapter Z1002 (100~240V, rated 1.7 A, 50/60 Hz)
Battery pack Z1003 (continuous usage time 8 hours, AC adapter connected for charging, charging time 5 hours 30 minutes)
Volume and weight 300W * 211H * 68D mm, 2.5 kg (including battery pack Z1003)
Attachment User manual *1, measurement guide *1, voltage line L1000-05 *1 (red, yellow, blue, gray, black, crocodile clamp *5, spiral tube *5), colored spiral tube (for distinguishing clamp sensor color) * set, spiral tube *5, AC adapter Z1002 *1, shoulder strap *1, USB cable (1 m) *1, battery pack Z1003 *1