Product Details
Place of Origin: Japan
Brand Name: HIOKI
Certification: CO
Model Number: CM4141-50
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: 360-500USD
Delivery Time: 6-8weeks
Payment Terms: T/T
Supply Ability: 99pcs/6-8weeks
|
Voltage Measurement:
|
Accurate
|
Display Resolution:
|
50,000 Count, 1/4 VGA Dot Matrix
|
Outputsignal:
|
4-20 MA, 0-10 V, Digital
|
Technology:
|
FieldSense
|
Application:
|
Industrial, HVAC, Automotive
|
Capture Speed:
|
250 Microseconds
|
Measurementrange:
|
0 To 1000 Psi
|
Wireless Compatibility:
|
Fluke Connect®
|
Display Backlight:
|
Large White LED
|
Peak Capture Speed:
|
250 μs
|
Mobile App Compatibility:
|
Fluke Connect
|
Design Feature:
|
OpenJaw™
|
Safety Rating:
|
CAT III 600 V
|
Resolution:
|
0.01 MV To 0.1 V
|
Responsetime:
|
≤ 1 Second
|
|
Voltage Measurement:
|
Accurate
|
|
Display Resolution:
|
50,000 Count, 1/4 VGA Dot Matrix
|
|
Outputsignal:
|
4-20 MA, 0-10 V, Digital
|
|
Technology:
|
FieldSense
|
|
Application:
|
Industrial, HVAC, Automotive
|
|
Capture Speed:
|
250 Microseconds
|
|
Measurementrange:
|
0 To 1000 Psi
|
|
Wireless Compatibility:
|
Fluke Connect®
|
|
Display Backlight:
|
Large White LED
|
|
Peak Capture Speed:
|
250 μs
|
|
Mobile App Compatibility:
|
Fluke Connect
|
|
Design Feature:
|
OpenJaw™
|
|
Safety Rating:
|
CAT III 600 V
|
|
Resolution:
|
0.01 MV To 0.1 V
|
|
Responsetime:
|
≤ 1 Second
|
| Parameter | Specifications |
|---|---|
| AC Current Range | 60.00 A to 2000 A, 3 ranges (45 to 1 kHz, true RMS rectified) Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (range 60 A) |
| Crest Factor | Measuring range 60.00 A: 2.5 (above 50.00 A is below 60.00 A) Measuring range 2000 A: 1.5 (below 2000 A) |
| DC Voltage Range | 600.0 mV to 1000 V (600.0 V to 2000 V when using P2000) |
| AC Voltage Range | 6.000 V to 1000 V, 4 ranges (15 to 1 kHz, true RMS rectified) Basic accuracy 45-66 Hz: ±0.9% rdg. ±0.003 V (at 6V) |
| AC + DC Voltage Range | 6.000 V to 1000 V, 4 ranges Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6V) |
| Resistance Range | 600.0 Ω to 6,000 MΩ, 5 measuring ranges Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
| Electrostatic Capacitance Range | 1.000 μF to 1000 μF, 4 measurement ranges Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
| Frequency Range | Voltage: 9.999 Hz to 999.9 Hz, 3 ranges Current: 99.99 Hz and 999.9 Hz, 2 ranges Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz) |
| Temperature (K) | -40.0 to 400.0 ˚C Accuracy: ±0.5% rdg. ±3.0 ˚C + temperature probe accuracy |