DC Voltage Range:
0.001 V To 1000 V
DC Voltage Range:
0.001 V To 1000 V
Fluke 15B+ Digital Multimeter DMM handheld tester providing accurate readings of voltage current resistance frequency
Product Overview

The Fluke 15B+ Digital Multimeter is a handheld tester engineered to deliver accurate, reliable readings of voltage, current, resistance, and frequency. Built for everyday troubleshooting and field diagnostics, it combines a rugged design with a large, easy-to-read backlit display and a 600 V CAT III safety rating.

Model: FLUKE-15B+ ESP Part No.: 4404210U UPC: 0 95969 69266 3

Key Features
  • 600 V CAT III safety rating
  • AC/DC voltage measurement up to 1000 V
  • AC/DC current measurement up to 10 A
  • Measures voltage, resistance, continuity, and capacitance
  • Diode test and data hold functions
  • Large, easy-to-read display with bright white backlight
Accuracy Specifications

Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C with relative humidity of 0% to 75%. Accuracy specifications take the form of ±(% of reading + number of least significant digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500 Hz)1
4.000 V 0.001 V 1.0% + 3
40.00 V 0.01 V 1.0% + 3
400.0 V 0.1 V 1.0% + 3
1000 V 1 V 1.0% + 3
DC volts 4.000 V 0.001 V 0.5% + 3
40.00 V 0.01 V 0.5% + 3
400.0 V 0.1 V 0.5% + 3
1000 V 1 V 0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance (Ohms) 400.0 Ω 0.1 Ω 0.5% + 3
4.000 kΩ 0.001 kΩ 0.5% + 2
40.00 kΩ 0.01 kΩ 0.5% + 2
400.0 kΩ 0.1 kΩ 0.5% + 2
4.000 MΩ 0.001 MΩ 0.5% + 2
40.00 MΩ 0.01 MΩ 1.5% + 3
Capacitance3 40.00 nF 0.01 nF 2% + 5
400.0 nF 0.1 nF 2% + 5
4.000 μF 0.001 μF 5% + 5
40.00 μF 0.01 μF 5% + 5
400.0 μF 0.1 μF 5% + 5
1000 μF 1 μF 5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA 1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA 1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A 1.5% + 3
DC current μA 400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA 1.5% + 3
DC current mA 40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA 1.5% + 3
DC current A 4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A 1.5% + 3
Backlight Yes
  • 1. AC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
  • 2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  • 3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Input Characteristics
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V1 >10 MΩ <100 pF >60 dB at DC, 50 Hz or 60 Hz —
AC millivolts 400 mV >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz —
DC volts 1000 V1 >10 MΩ <100 pF >100 dB at DC, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz —
  • 1. 106 V·Hz maximum.
General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum
Operating temperature 0 °C to 40 °C
Storage temperature -30 °C to 60 °C
Operating humidity Non-condensing (<10 °C); ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C; 40 MΩ range: ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C
Operating altitude 2000 m
Storage altitude 12,000 m
Temperature coefficient 0.1 × (specified accuracy) / °C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse (Fluke specified part only); 11 A, 1000 V Fast Fuse (Fluke specified part only)
Size (H × W × L) 183 × 91 × 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC 61010-2-030 CAT III 600 V, Pollution Degree 2
Electromagnetic compatibility IEC 61326-1: Portable EMC Environment