Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
상품
상품
> 상품 > ‌Water Quality Analyzer > HACH Total Phosphorus TNT Reagent TNT 832 with Pre-dosed Reagent Vials, Barcode Technology, and Truecal Lot-Specific Calibration for Water Quality Analysis

HACH Total Phosphorus TNT Reagent TNT 832 with Pre-dosed Reagent Vials, Barcode Technology, and Truecal Lot-Specific Calibration for Water Quality Analysis

제품 상세정보

브랜드 이름: HACH

모델 번호: TNT 832

문서: TNT--DOC0525325018-TNTplus.pdf

지불과 운송 용어

최소 주문 수량: 1

가격: 49.9 SUD

배달 시간: 6-8 주

지불 조건: 티/티

공급 능력: 1PC 6-8주

지금 챗팅하세요
강조하다:

Pre-dosed Reagent Vials Total Phosphorus TNT Reagent

,

Barcode Technology Water Quality Analyzer Reagent

,

Truecal Lot-Specific Calibration Phosphorus Testing Reagent

데이터 저장:
수천 개의 판독값을 저장할 수 있는 내부 메모리
치수:
다양함(예: 휴대용의 경우 200mm x 80mm x 40mm)
제품명:
수질 분석기
방수등급:
휴대용 장치의 경우 IP67 이상
응답 시간:
일반적으로 30초 미만
무게:
모델에 따라 일반적으로 300g ~ 1.5kg
표시 유형:
디지털 LCD 또는 LED 화면
측정 범위:
매개변수에 따라 다릅니다(예: pH 0-14, DO 0-20 mg/L)
측정 매개변수:
pH, 용존 산소, 탁도, 전도도, 총 용존 고형물(TDS), 염도, 온도, 암모니아, 질산염, 인산염
작동 온도:
0°C ~ 50°C(모델에 따라 다름)
전원 공급 장치:
배터리 전원 또는 AC 어댑터
구경 측정:
표준 용액을 사용한 수동 또는 자동 교정
데이터 출력:
USB, Bluetooth, RS232 또는 SD 카드
정확성:
일반적으로 ±0.01 pH, ±0.1 mg/L DO
이식성:
휴대용 또는 벤치탑 모델 사용 가능
데이터 저장:
수천 개의 판독값을 저장할 수 있는 내부 메모리
치수:
다양함(예: 휴대용의 경우 200mm x 80mm x 40mm)
제품명:
수질 분석기
방수등급:
휴대용 장치의 경우 IP67 이상
응답 시간:
일반적으로 30초 미만
무게:
모델에 따라 일반적으로 300g ~ 1.5kg
표시 유형:
디지털 LCD 또는 LED 화면
측정 범위:
매개변수에 따라 다릅니다(예: pH 0-14, DO 0-20 mg/L)
측정 매개변수:
pH, 용존 산소, 탁도, 전도도, 총 용존 고형물(TDS), 염도, 온도, 암모니아, 질산염, 인산염
작동 온도:
0°C ~ 50°C(모델에 따라 다름)
전원 공급 장치:
배터리 전원 또는 AC 어댑터
구경 측정:
표준 용액을 사용한 수동 또는 자동 교정
데이터 출력:
USB, Bluetooth, RS232 또는 SD 카드
정확성:
일반적으로 ±0.01 pH, ±0.1 mg/L DO
이식성:
휴대용 또는 벤치탑 모델 사용 가능
HACH Total Phosphorus TNT Reagent TNT 832 with Pre-dosed Reagent Vials, Barcode Technology, and Truecal Lot-Specific Calibration for Water Quality Analysis
HACH Total Phosphorus TNT Reagent TNT 832
Advanced reagent system for precise total phosphorus measurement in water analysis applications.
TNTplus Vial Chemistry Technology
  • Pre-dosed reagent vials with freeze-dried reagents in sealed containers
  • Integrated barcode system for automated processing
  • Eliminates manual reagent measuring and reduces contamination risk
Automated Barcode Technology
Unique barcode on each vial is automatically read by Hach spectrophotometers, eliminating manual method selection and ensuring consistent testing protocols.
Precision Measurement Logic
Instrument takes 10 readings around vial circumference, averages results, and automatically rejects outliers. This advanced methodology minimizes errors from glassware flaws, scratches, or dirty vials.
Calibration System
Truecal lot-specific calibration data included with each batch reduces batch-to-batch variability and improves result reliability for consistent analytical performance.
Workflow Efficiency
No reagent blank required for testing, saving time and consumables while simplifying laboratory workflow and reducing operational costs.
Traceability and Compliance
2D barcode includes lot number and expiration date stored with results, ensuring full compliance and auditability for regulatory requirements and quality assurance protocols.
Safety Design Features
Sealed vial and Dosicap™ system minimizes chemical exposure, reducing spillage and handling hazards for laboratory personnel while maintaining reagent integrity.
Traditional Test 'N Tube Option
Also available as traditional cuvette-based reagent sets requiring manual reagent addition for compatibility with legacy Hach instruments at lower upfront cost.