Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
상품
상품
> 상품 > Pressure Measurement Instruments‌ > WINTERS LY21-A Sanitary Pressure Transmitter with 0.1% Accuracy, IP67 Protection, and 4-20 mA Output

WINTERS LY21-A Sanitary Pressure Transmitter with 0.1% Accuracy, IP67 Protection, and 4-20 mA Output

제품 상세정보

브랜드 이름: WINTERS

모델 번호: LY21-A

문서: LV21.pdf

지불과 운송 용어

최소 주문 수량: 1

가격: 100USD

배달 시간: 6-8 주

지불 조건: 티/티

공급 능력: 1PC 6-8주

지금 챗팅하세요
강조하다:

sanitary pressure transmitter with IP67

,

high accuracy pressure transmitter 0.1%

,

4-20 mA output pressure transmitter

출력 범위:
0.5~4.5V 또는 4~20mA
진입 보호:
IP67
응답 시간:
< 10ms
스팬 출력:
50±10mV(≤20KPa),100±10mV(≥35KPa)
출력 신호:
4-20 MA
작동 온도:
-40 내지 85 'C
생산지:
중국 저장성
압력 범위:
0-100MPa
범위:
-0.1~100MPa
영점 조정:
수동/자동
보호:
IP65
측정 범위:
0~1000바
출력 압력:
0~350KPa, 10~800KPa
인증서:
폭발 방지 인증서
중간:
가스, 액체
출력 범위:
0.5~4.5V 또는 4~20mA
진입 보호:
IP67
응답 시간:
< 10ms
스팬 출력:
50±10mV(≤20KPa),100±10mV(≥35KPa)
출력 신호:
4-20 MA
작동 온도:
-40 내지 85 'C
생산지:
중국 저장성
압력 범위:
0-100MPa
범위:
-0.1~100MPa
영점 조정:
수동/자동
보호:
IP65
측정 범위:
0~1000바
출력 압력:
0~350KPa, 10~800KPa
인증서:
폭발 방지 인증서
중간:
가스, 액체
WINTERS LY21-A Sanitary Pressure Transmitter with 0.1% Accuracy, IP67 Protection, and 4-20 mA Output
WINTERS LY21-A Sanitary Pressure Transmitter
High-performance hygienic pressure transmitter with 0.1% accuracy, IP67 protection, and 4-20 mA output for demanding sanitary applications.
Product Overview
The WINTERS LY21-A is a high-performance hygienic pressure transmitter specifically designed for sanitary applications in industrial and manufacturing processes. Engineered with precision and reliability in mind, this transmitter meets the stringent requirements of hygienic processing environments.
Technical Specifications
ModelWINTERS LY21 Series (Hygienic Pressure Transmitter)
TypePiezoresistive Silicon Pressure Transmitter (Hygienic Application)
Measurement PrinciplePiezoresistive Silicon
Pressure Range0…10 kPa to 0…2.5 MPa (Gauge, Absolute, Vacuum)
Accuracy (25°C)±0.2% FSO (Standard); ±0.1% FSO (Optional)
Includes linearity, repeatability, hysteresis, zero & span shift
Zero Temperature Coefficient≤0.02% of FS per °C
Span Temperature Coefficient≤0.02% of FS per °C
Long Term Stability0.2% of FS per year
Span AdjustmentMax 10:1 Turndown Ratio
Enclosure RatingIP67 (EN 60529)
Compensated Temperature-20°C to 85°C (-4°F to 185°F)
Ambient Temperature-20°C to 70°C (-4°F to 158°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Media TemperatureWithout Radiator: -40°C to 120°C (-40°F to 248°F)
With Radiator: -40°C to 200°C (-40°F to 392°F)
Output Signal4-20 mA Two-Wire
Supply Voltage10.5-30 VDC (Recommended: 24 VDC)
Load ResistanceRL ≤ (Us - 10.5 V) / 21 mA
Vibration Resistance10 g, 25 Hz to 2 kHz
Shock Resistance500 g, 1 ms
Insulation Resistance>20 MΩ at 100 VDC
Response Time (10%-90%)≤10 ms
Electrical ProtectionReverse Polarity Protection, Overvoltage Protection, Short Circuit Protection
Wetted Parts316L Stainless Steel (Standard); Hastelloy C (Optional)
Diaphragm Surface RoughnessRa ≤ 0.4 μm
Process ConnectionTri-Clamp (1.5", 2"), DIN32676 (DN32, DN40, DN50), ISO2852, DIN11851, SMS
Certifications3A Sanitary Standard, SIP/CIP Compatible
ConstructionAll-Welded Sensor
Electrical ConnectionM12 * 1 Connector (4-pin)
Mounting StyleRadial (Standard), Axial (Optional)
RadiatorWithout (Standard), With (Optional)
Life Cycle10,000,000 Pressure Cycles
ComplianceRoHS Compliant
Key Features
  • Hygienic design compliant with 3A Sanitary Standard
  • SIP/CIP compatible for easy cleaning and sterilization
  • High accuracy with ±0.2% FSO standard performance
  • Robust IP67 rated enclosure for harsh environments
  • All-welded sensor construction for maximum reliability
  • Wide temperature range operation with optional radiator
  • Multiple process connection options for flexible installation
  • Long life cycle of 10 million pressure cycles
Industrial Applications
Ideal for food & beverage, pharmaceutical, biotechnology, and chemical processing industries where sanitary conditions and precise pressure measurement are critical.