Honeywell SPXCDULNO2R Toxic Gas Detector With RS485 MODBUS Output 3 X 5A@250VAC Relays

Detalles del producto

Lugar de origen: Porcelana

Nombre de la marca: Honeywell

Certificación: CO

Número de modelo: SPXCDULNO2R

Documento: DS01154_Sensepoint XCD RTD ...12.pdf

Pago y términos de envío

Cantidad de orden mínima: 1

Precio: 2556$

Tiempo de entrega: 5-8 días de trabajo

Condiciones de pago: T/T

Resaltar:

SPXCDULNO2R Toxic Gas Detector

,

Honeywell Toxic Gas Detector

Rango de voltaje de entrada:
16 a 32 VCC (24 VCC nominales)
Consumo máximo de energía:
3,7W (celdas electroquímicas)
Max Inrush Current:
800 mA a 24 VCC
Salida actual:
Cubo o fuente
Retransmisiones:
3 x 5A@250VAC, seleccionable NO/NC
Comunicación:
RS485
Material de la carcasa:
Aleación de aluminio pintada con epoxi LM25 o acero inoxidable 316.
peso:
4,4 libras (aleación de aluminio LM25), 11 libras (acero inoxidable 316)
Rango de voltaje de entrada:
16 a 32 VCC (24 VCC nominales)
Consumo máximo de energía:
3,7W (celdas electroquímicas)
Max Inrush Current:
800 mA a 24 VCC
Salida actual:
Cubo o fuente
Retransmisiones:
3 x 5A@250VAC, seleccionable NO/NC
Comunicación:
RS485
Material de la carcasa:
Aleación de aluminio pintada con epoxi LM25 o acero inoxidable 316.
peso:
4,4 libras (aleación de aluminio LM25), 11 libras (acero inoxidable 316)
Honeywell SPXCDULNO2R Toxic Gas Detector With RS485 MODBUS Output 3 X 5A@250VAC Relays
Honeywell SPXCDULNO2R toxic gas detector
Advanced 3-wire fixed point detector with 4-20mA and RS485 MODBUS output, featuring built-in alarm and fault relays for comprehensive protection against toxic and oxygen hazards. This transmitter includes local display and supports optional remote mounted sensors, fully configurable via non-intrusive magnetic switch interface.
Electrical Specifications
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Electrochemical cells = 3.7W
Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable). Alarm relays default normally open/de-energized. Fault relay default normally open/energized.
Communication RS485
Construction Details
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: Polyphenylene sulfide (PPS)
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries 2 x 3/4" NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating
Environmental Specifications
IP Rating IP67 in accordance with EN60529:1992
Certified Temperature Range 40°F to +149°F (-40°C to +65°C)
Key Features
  • 3-wire configuration with dual output options
  • Built-in alarm and fault relays for safety
  • Local display with remote sensor capability
  • Non-intrusive magnetic switch configuration
  • Wide range of integral and remote sensors available
  • Robust construction for industrial environments