Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
produtos
produtos
Casa > produtos > Gas Detectors > Honeywell SPXCDULNO2R Toxic Gas Detector With RS485 MODBUS Output 3 X 5A@250VAC Relays

Honeywell SPXCDULNO2R Toxic Gas Detector With RS485 MODBUS Output 3 X 5A@250VAC Relays

Detalhes do produto

Lugar de origem: China

Marca: Honeywell

Certificação: CO

Número do modelo: SPXCDULNO2R

Documento: DS01154_Sensepoint XCD RTD ...12.pdf

Termos do pagamento & do transporte

Quantidade de ordem mínima: 1

Preço: 2556$

Tempo de entrega: 5-8 dias de trabalho

Termos de pagamento: T/T

Converse agora
Destacar:

SPXCDULNO2R Toxic Gas Detector

,

Honeywell Toxic Gas Detector

Faixa de tensão de entrada:
16 a 32 VCC (24 VCC nominal)
Consumo máximo de energia:
3,7W (células eletroquímicas)
Max Inrush Current:
800mA a 24VCC
Saída atual:
Fonte ou sumidouro
Relés:
3 x 5A@250VAC, selecionável NO/NC
Comunicação:
RS485
Material de habitação:
Liga de alumínio pintada com epóxi LM25 ou aço inoxidável 316
peso:
4,4 libras (liga de alumínio LM25), 11 libras (aço inoxidável 316)
Faixa de tensão de entrada:
16 a 32 VCC (24 VCC nominal)
Consumo máximo de energia:
3,7W (células eletroquímicas)
Max Inrush Current:
800mA a 24VCC
Saída atual:
Fonte ou sumidouro
Relés:
3 x 5A@250VAC, selecionável NO/NC
Comunicação:
RS485
Material de habitação:
Liga de alumínio pintada com epóxi LM25 ou aço inoxidável 316
peso:
4,4 libras (liga de alumínio LM25), 11 libras (aço inoxidável 316)
Honeywell SPXCDULNO2R Toxic Gas Detector With RS485 MODBUS Output 3 X 5A@250VAC Relays
Honeywell SPXCDULNO2R toxic gas detector
Advanced 3-wire fixed point detector with 4-20mA and RS485 MODBUS output, featuring built-in alarm and fault relays for comprehensive protection against toxic and oxygen hazards. This transmitter includes local display and supports optional remote mounted sensors, fully configurable via non-intrusive magnetic switch interface.
Electrical Specifications
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Electrochemical cells = 3.7W
Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable). Alarm relays default normally open/de-energized. Fault relay default normally open/energized.
Communication RS485
Construction Details
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: Polyphenylene sulfide (PPS)
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries 2 x 3/4" NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating
Environmental Specifications
IP Rating IP67 in accordance with EN60529:1992
Certified Temperature Range 40°F to +149°F (-40°C to +65°C)
Key Features
  • 3-wire configuration with dual output options
  • Built-in alarm and fault relays for safety
  • Local display with remote sensor capability
  • Non-intrusive magnetic switch configuration
  • Wide range of integral and remote sensors available
  • Robust construction for industrial environments