Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
leonleesale@aliyun.com 86--15389206502
produkty
produkty
Do domu > produkty > Industrial Sensors‌ > HART 7 PR 3337 Temperature Converter Loop-Powered 0.05% Accuracy Pre-Calibrated Ranges

HART 7 PR 3337 Temperature Converter Loop-Powered 0.05% Accuracy Pre-Calibrated Ranges

Szczegóły produktu

Miejsce pochodzenia: Dania

Nazwa handlowa: PR

Orzecznictwo: CO

Numer modelu: PR 3337

Dokument: 3337v107_en.pdf

Warunki płatności i wysyłki

Minimalne zamówienie: 1

Cena: 200-500usd

Czas dostawy: 5-7 dni roboczych

Zasady płatności: T/T

Możliwość Supply: 99 sztuk 4-6 tygodni

Rozmawiaj teraz.
Podkreślić:

HART 7 temperature transmitter with warranty

,

loop powered temperature transmitter 0.05% accuracy

,

pre calibrated temperature transmitter selectable response

Wyjście:
4-20mADC/1-5VDC
Zakres pomiarowy:
-200°C do 850°C
Typ produktu:
Kontroler MD-PLUS
Korzystanie z zasięgu:
Temperatura
Połączenie elektryczne:
Zaciski śrubowe
waga:
0,5 kg
Materiał obudowy:
Stal nierdzewna
Typ siłownika:
Obrót boczny - bez dźwigni
Typ mocowania:
Montaż na szynie DIN lub w terenie
Dokładności:
do 0,035% standardowo i 0,025% opcjonalnie
Ochrona wejściowa:
Wewnętrznie zabezpieczone, niewymienne
uszczelka:
nowe i oryginalne z fabryczną plombą
Szacowany czas realizacji:
1-2 tygodnie
Dostępność:
w magazynie
Medium pomiarowe:
Gaz i ciecz kompatybilne z 316LSS
Wyjście:
4-20mADC/1-5VDC
Zakres pomiarowy:
-200°C do 850°C
Typ produktu:
Kontroler MD-PLUS
Korzystanie z zasięgu:
Temperatura
Połączenie elektryczne:
Zaciski śrubowe
waga:
0,5 kg
Materiał obudowy:
Stal nierdzewna
Typ siłownika:
Obrót boczny - bez dźwigni
Typ mocowania:
Montaż na szynie DIN lub w terenie
Dokładności:
do 0,035% standardowo i 0,025% opcjonalnie
Ochrona wejściowa:
Wewnętrznie zabezpieczone, niewymienne
uszczelka:
nowe i oryginalne z fabryczną plombą
Szacowany czas realizacji:
1-2 tygodnie
Dostępność:
w magazynie
Medium pomiarowe:
Gaz i ciecz kompatybilne z 316LSS
HART 7 PR 3337 Temperature Converter Loop-Powered 0.05% Accuracy Pre-Calibrated Ranges
HART 7 Temperature Converter, Loop-Powered
PR 3337
Key Features
  • Excellent accuracy, better than 0.05% of span
  • Superior EMC performance
  • Selectable 60 ms / 60 s response time
  • Pre-calibrated temperature ranges
Product Overview

The HART 7 temperature converter offers precision temperature measurement with loop-powered operation, designed for industrial applications requiring reliable and accurate temperature monitoring.

Environmental Conditions
Operating temperature-25°C to +70°C
Storage temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degreeIP20
Installation environmentPollution degree 2 & measurement/overvoltage category II
Mechanical Specifications
Dimensions (HxWxD)113 x 6.1 x 115 mm
Weight approx.70 g
DIN rail typeDIN EN 60715/35 mm
Wire size0.13...2.5 mm² / AWG 26...12 stranded wire
Screw terminal torque0.5 Nm
Vibration complianceIEC 60068-2-6
Electrical Specifications
Power Supply
Supply voltage6.2...35 VDC
Maximum required power0.80 W
Internal power dissipation22 mW...0.8 W
Isolation & Protection
Isolation voltage, test/working2.5 kVAC / 300 VAC (reinforced)
Zone 2 / Division 2 rating250 VAC
Performance Characteristics
Response time (HART mode)60 ms...60 s, programmable
Response time (DIP mode)< 60 ms
Voltage drop6.2 VDC
Signal/noise ratioMinimum 60 dB
Signal dynamics, input23 bit
Signal dynamics, output18 bit
EMC immunity influence< ±0.5% of span
Input Specifications
RTD Input
Temperature range, Pt100-200...+850°C
AccuracyBetter than 0.05% of span or 0.1°C
Temperature coefficient0.02°C/°C or ≤ ±0.01%/°C
Sensor current< 150 µA
Sensor cable resistance< 50 Ω per wire
Sensor error detectionYes - selectable via DIP-switch
Thermocouple Input
Temperature range, TC J-100...+1200°C
Temperature range, TC K-180...+1372°C
AccuracyBetter than 0.05% of span or 0.5°C
Temperature coefficient0.1°C/°C or ≤ ±0.01%/°C
Cold junction compensation accuracyBetter than ±0.15°C (external) / ±2.5°C (internal)
Output Specifications
Updating time10 ms
Programmable signal ranges4...20 and 20...4 mA
HART protocol revisionsHART 7
Safety Certifications & Approvals
International Safety Standards
ATEXII 3 G Ex ec IIC T4 Gc
IECExEx ec IIC T4 Gc
FM, USCl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CACl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
EAC Ex2Ex nA IIC T4 Gc X
Compliance Certifications
ATEXKEMA 10ATEX0147 X
IECExKEM 10.0068X
UKEXDEKRA 21UKEX0055X
c FM usFM17US0004X / FM17CA0003X
c UL us, UL 61010-1E314307
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA00001RW
Regulatory Compliance
EMC2014/30/EU & UK SI 2016/1091
LVD2014/35/EU & UK SI 2016/1101
ATEX2014/34/EU & UK SI 2016/1107
RoHS2011/65/EU & UK SI 2012/3032
EACTR-CU 020/2011
EAC ExTR-CU 012/2011